INTRODUCTION
One
of the most promising renewable energy technologies is photovoltaics.
Photovoltaics (PV) is a truly elegant means of producing electricity on
site, directly from the sun, without concern for energy supply or
environmental harm. These solid-state devices simply make electricity
out of sunlight, silently with no maintenance, no pollution, and no
depletion of materials.
There is a growing consensus that
distributed photovoltaic systems that provide electricity at the point
of use will be the first to reach widespread commercialization. Chief
among these distributed applications are PV power systems for
individual buildings.
Interest in the building integration
of photovoltaics, where the PV elements actually become an integral
part of the building, often serving as the exterior weather skin, is
growing worldwide. PV specialists and innovative designers in Europe,
Japan, and the U.S. are now exploring creative ways of incorporating
solar electricity into their work. A whole new vernacular of Solar
Electric Architecture is beginning to emerge.
A Building
Integrated Photovoltaics (BIPV) system consists of integrating
photovoltaics modules into the building envelope, such as the roof or
the façade. By simultaneously serving as building envelope material and
power generator, BIPV systems can provide savings in materials and
electricity costs, reduce use of fossil fuels and emission of ozone
depleting gases, and add architectural interest to the building.
 |
A PV skylight entryway (Courtesy of DOE/NREL) |
While
the majority of BIPV systems are interfaced with the available utility
grid, BIPV may also be used in stand-alone, off-grid systems. One of
the benefits of grid-tied BIPV systems is that, with a cooperative
utility policy, the storage system is essentially free. It is also 100%
efficient and unlimited in capacity. Both the building owner and the
utility benefit with grid-tied BIPV. The on-site production of solar
electricity is typically greatest at or near the time of a building's
and the utility's peak loads. The solar contribution reduces energy
costs for the building owner while the exported solar electricity helps
support the utility grid during the time of its greatest demand.
DESCRIPTION
Photovoltaics (PV) Technologies
There are two basic commercial PV module technologies available on the market today:
- Thick crystal products
include solar cells made from crystalline silicon either as single or
poly-crystalline wafers and deliver about 10-12 watts per ft² of PV
array (under full sun).
- Thin-film products
typically incorporate very thin layers of photovoltaicly active
material placed on a glass superstrate or a metal substrate using
vacuum-deposition manufacturing techniques similar to those employed in
the coating of architectural glass. Presently, commercial thin-film
materials deliver about 4-5 watts per ft² of PV array area (under full
sun). Thin-film technologies hold out the promise of lower costs due to
much lower requirements for active materials and energy in their
production when compared to thick-crystal products.
A
photovoltaic system is constructed by assembling a number of individual
collectors called modules electrically and mechanically into an array.
Building Integrated Photovoltaics (BIPV) System
Building
Integrated Photovoltaics (BIPV) is the integration of photovoltaics
(PV) into the building envelope. The PV modules serve the dual function
of building skin—replacing conventional building envelope materials—and
power generator. By avoiding the cost of conventional materials, the
incremental cost of photovoltaics is reduced and its life-cycle cost is
improved. That is, BIPV systems often have lower overall costs than PV
systems requiring separate, dedicated, mounting systems.
A complete BIPV system includes:
- the PV modules (which might be thin-film or crystalline, transparent, semi-transparent, or opaque);
- a charge controller, to regulate the power into and out of the battery storage bank (in stand-alone systems);
- a
power storage system, generally comprised of the utility grid in
utility-interactive systems or, a number of batteries in stand-alone
systems;
- power conversion equipment including an inverter to convert the PV modules' DC output to AC compatible with the utility grid;
- backup power supplies such as diesel generators (optional-typically employed in stand-alone systems); and
- appropriate support and mounting hardware, wiring, and safety disconnects.
BIPV
systems can either be interfaced with the available utility grid or
they may be designed as stand-alone, off-grid systems. The benefits of
power production at the point of use include savings to the utility in
the losses associated with transmission and distribution (known as
'grid support'), and savings to the consumer through lower electric
bills because of peak shaving (matching peak production with periods of
peak demand). Moreover, buildings that produce power using renewable
energy sources reduce the demands on traditional utility generators,
often reducing the overall emissions of climate-change gasses.
Design of a Building Integrated Photovoltaics (BIPV) System
BIPV
systems should be approached to where energy conscious design
techniques have been employed, and equipment and systems have been
carefully selected and specified. They should be viewed in terms of
life-cycle cost, and not just initial, first-cost because the overall
cost may be reduced by the avoided costs of the building materials and
labor they replace. Design considerations for BIPV systems must include
the building's use and electrical loads, its location and orientation,
the appropriate building and safety codes, and the relevant utility
issues and costs.
Steps in designing a BIPV system include:
- Carefully
consider the application of energy-conscious design practices and/or
energy-efficiency measures to reduce the energy requirements of the
building. This will enhance comfort and save money while also
enabling a given BIPV system to provide a greater percentage
contribution to the load.
- Choose Between a Utility-Interactive PV System and a Stand-alone PV System:
- The
vast majority of BIPV systems will be tied to a utility grid, using the
grid as storage and backup. The systems should be sized to meet the
goals of the owner—typically defined by budget or space constraints;
and, the inverter must be chosen with an understanding of the
requirements of the utility.
- For
those 'stand-alone' systems powered by PV alone, the system, including
storage, must be sized to meet the peak demand/lowest power production
projections of the building. To avoid over sizing the PV/battery system
for unusual or occasional peak loads, a backup generator is often used.
This kind of system is sometimes referred to as a "PV-genset hybrid."
- Shift the Peak:
If the peak building loads do not match the peak power output of the PV
array, it may be economically appropriate to incorporate batteries into
certain grid-tied systems to offset the most expensive power demand
periods. This system could also act as an uninterruptible power system
(UPS).
- Provide Adequate Ventilation:
PV conversion efficiencies are reduced by elevated operating
temperatures. This is truer with crystalline silicon PV cells than
amorphous silicon thin-films. To improve conversion efficiency, allow
appropriate ventilation behind the modules to dissipate heat.
- Evaluate Using Hybrid PV-Solar Thermal Systems:
As an option to optimize system efficiency, a designer may choose to
capture and utilize the solar thermal resource developed through the
heating of the modules. This can be attractive in cold climates for the
pre-heating of incoming ventilation make-up air.
- Consider Integrating Daylighting and Photovoltaic Collection:
Using semi-transparent thin-film modules, or crystalline modules with
custom-spaced cells between two layers of glass, designers may use PV
to create unique daylighting features in façade, roofing, or skylight
PV systems. The BIPV elements can also help to reduce unwanted cooling
load and glare associated with large expanses of architectural glazing.
- Incorporate PV Modules into Shading Devices:
PV arrays conceived as "eyebrows" or awnings over view glass areas of a
building can provide appropriate passive solar shading. When sunshades
are considered as part of an integrated design approach, chiller
capacity can often be smaller and perimeter cooling distribution
reduced or even eliminated.
- Design for the Local Climate and Environment:
Designers should understand the impacts of the climate and environment
on the array output. Cold, clear days will increase power production,
while hot, overcast days will reduce array output;
- Surfaces reflecting light onto the array (e.g., snow) will increase the array output;
- Arrays must be designed for potential snow- and wind-loading conditions;
- Properly angled arrays will shed snow loads relatively quickly; and,
- Arrays
in dry, dusty environments or environments with heavy industrial or
traffic (auto, airline) pollution will require washing to limit
efficiency losses.
- Address Site Planning and Orientation Issues:
Early in the design phase, ensure that your solar array will receive
maximum exposure to the sun and will not be shaded by site obstructions
such as nearby buildings or trees. It is particularly important that
the system be completely unshaded during the peak solar collection
period consisting of three hours on either side of solar noon. The
impact of shading on a PV array has a much greater influence on the
electrical harvest than the footprint of the shadow.
- Consider Array Orientation:
Different array orientation can have a significant impact on the annual
energy output of a system, with tilted arrays generating 50%-70% more
electricity than a vertical façade.
- Reduce Building Envelope and Other On-site Loads:
Minimize the loads experienced by the BIPV system. Employ daylighting,
energy-efficient motors, and other peak reduction strategies whenever
possible.
- Professionals:
The use of BIPV is relatively new. Ensure that the design,
installation, and maintenance professionals involved with the project
are properly trained, licensed, certified, and experienced in PV
systems work.
In addition, BIPV systems can be
designed to blend with traditional building materials and designs, or
they may be used to create a high-technology, future-oriented appearance.
Semi-transparent arrays of spaced crystalline cells can provide
diffuse, interior natural lighting. High profile systems can also
signal a desire on the part of the owner to provide an environmentally
conscious work environment.
APPLICATION
Photovoltaics may be integrated into many different assemblies within a building envelope:
- Solar
cells can be incorporated into the façade of a building, complementing
or replacing traditional view or spandrel glass. Often, these
installations are vertical, reducing access to available solar
resources, but the large surface area of buildings can help compensate
for the reduced power.
- Photovoltaics
may be incorporated into awnings and saw-tooth designs on a building
façade. These increase access to direct sunlight while providing
additional architectural benefits such as passive shading.
- The
use of PV in roofing systems can provide a direct replacement for
batten and seam metal roofing and traditional 3-tab asphalt shingles.
- Using PV for skylight systems can be both an economical use of PV and an exciting design feature.
 
Left to right: APS Factory in Fairfield, CA and Intercultural Center, Georgetown University in Washington, DC |
RELEVANT CODES AND STANDARDS
ADDITIONAL RESOURCES
WBDG
Building Types
Applicable to all building types
Design Objectives
Aesthetics, Sustainable
Products and Systems
Building Envelope Design Guide: Exterior Insulation and Finish System (EIFS), Masonry Wall Systems, Panelized Metal Wall Systems, Precast Concrete Wall Systems, Thin Stone Wall Systems, Roofing Systems
Manufacturers and Suppliers
Computer-Based PV Design and Sizing Tools
PV F-Chart—Provides analysis and rough sizing of both grid-connected and stand-alone PV systems.
PVFORM—Offers simulation of grid-connected and stand-alone systems, including economic analysis. Available from Sandia National Labs, Albuquerque, NM.
TRNSYS—Simulation system for renewable energy applications; originally for solar thermal, now has extensions for PV and wind.
HOMER—Hybrid
Optimization Model for Electric Renewables (HOMER) is a design
optimization model that determines the configuration, dispatch, and
load management strategy that minimizes life-cycle costs.
PVnode—Calculates
the electric behavior of large and inhomogeneously illuminated PV
arrays. Available from D. Stellbogen, ZSW Baden-Wurttemberg
Hessbruhlstr., 21c, D-70565 Stuttgart, Germany.
Updated: 07-25-2006
|